10 m³
The aircraft refueller has been designed for airplanes refueling with filtered aviation fuel both pure and mixed with fuel system icing inhibitor agents. It is in full compliance with allowable loads on thoroughfare. It has a vehicle type approval and a certificate of conformity GOST 52 906-2008. The aircraft refueller is used in airports of all the classes at air temperature from -40C to +40C and relative air humidity no more than 95%.
Configuration | Standard |
---|---|
Tank capacity |
10 700 liters |
Tank material |
Stainless steel |
Pump output flow at underwing refueling |
500 l/min |
Recommended pump output flow at overwing refueling via refueling nozzle |
400 l/min |
Dosing fuel system icing inhibitor agents |
0; 0,1% (as an option 0,2%, 0,3%) |
Maximum allowable pressure in a dispensing hose before the end of the tip of a bottom filling nozzle | < = 4,5 kg/sm² |
Nominal filtration rating |
1–3 microns |
Maximum allowable water content (by weight) |
0,0015% |
Main consumption indicator error, % |
±0,25% |
Dispensing hoses (number x length, m x diameter, mm) |
1 x 20 x 50, (as an option) 1 x 20 x 38 |
Bottom filling nozzle |
1 x Meggitt F145 |
Rrefueling nozzle |
1 x Elaflex ZVF-40 |
Pumping unit |
Alfons Haar FPO 80 |
A calculating and metering system |
Alfons Haar MKA-800 DKP |
Filter – water separator |
Scientific Production Association “Agregat”, FVKg-56-65 |
Refueling hoses |
Elaflex |
The Inline valve |
Electromagnetic |
A level gauge, a tank filling limiter system |
Electronic |
An administration panel |
Mechanical |
System of control for operator’s condition (“Dead man”) |
Installed |
System of blocking rooter’s movement (Interlock) |
Installed |
System of earthing |
Two earthing reels with a 30 meters length cable |
Painting |
By client’s coloring map including a company logo |
Tank capacity:
10 700 liters
Tank material:
Stainless steel
Pump output flow at underwing refueling:
500 l/min
Recommended pump output flow at overwing refueling via refueling nozzle:
400 l/min
Dosing fuel system icing inhibitor agents:
0; 0,1% (as an option 0,2%, 0,3%)
Maximum allowable pressure in a dispensing hose before the end of the tip of a bottom filling nozzle:
< = 4,5 kg/sm²
Nominal filtration rating:
1–3 microns
Maximum allowable water content (by weight):
0,0015%
Main consumption indicator error, %:
±0,25%
Dispensing hoses (number x length, m x diameter, mm):
1 x 20 x 50, (as an option) 1 x 20 x 38
Bottom filling nozzle:
1 x Meggitt F145
Rrefueling nozzle:
1 x Elaflex ZVF-40
Pumping unit:
Alfons Haar FPO 80
A calculating and metering system:
Alfons Haar MKA-800 DKP
Filter – water separator:
Scientific Production Association “Agregat”, FVKg-56-65
Refueling hoses:
Elaflex
The Inline valve :
Electromagnetic
A level gauge, a tank filling limiter system:
Electronic
An administration panel:
Mechanical
System of control for operator’s condition (“Dead man”) :
Installed
System of blocking rooter’s movement (Interlock):
Installed
System of earthing:
Two earthing reels with a 30 meters length cable
Painting: