20 m³

20 m³

The aircraft refueller has been designed for airplanes refueling with filtered aviation fuel both pure and mixed with fuel system icing inhibitor agents. It is in full compliance with allowable loads on thoroughfare. It has a vehicle type approval and a certificate of conformity GOST 52 906-2008.  The aircraft refueller is used in airports of all the classes at air temperature from -400C to +400C and relative air humidity no more than 95%. 

20 м3 tank capacity
Case shaped cross-section
One compartment
Top and bottom refueling
Possibility of dosing fuel system icing inhibitor agents

If you need more information about this model, please, fill in the form below.

E-mail
Name
Telephone
Company
CAPTCHA
CAPTCHA
Type the letters you see on the picture*
Close form
Technical parameters
Configuration Standard Extended
Tank capacity
20 000 liters 20 000 liters
Tank material
Aluminium alloy
Aluminium alloy

Pump output flow at underwing refueling

via one hose

via two hoses


   

≥ 1 000 l/min 

______

   

 ≥ 1 000 l/min  

≥ 2 000 l/min 
Recommended pump output flow at overwing refueling via refueling nozzle
400 l/min  400 l/min 
Dosing fuel system icing inhibitor agents
0; 0,1% (as an option up to 0,3%)
0; 0,1% (as an option up to 0,3%)
Maximum allowable pressure in a dispensing hose before a bottom filling nozzle
≤ 4,5 kg/sm2 ≤ 4,5 kg/sm2
Nominal filtration rating
1–3 microns 1–3 microns
Maximum allowable water content (by weight)
0,003% 0,003%
Main consumption indicator error
±0,25% ±0,25%
Dispensing hoses (number x length, m x diameter, mm)
1 x 25 x 63, 1 x 25 x 38 2 x 25 x 50

Bottom filling nozzle

1 x Meggitt F145 1 x Meggitt F145
Refueling nozzle
1 x Elaflex ZVA-40 1 x Elaflex ZVA-40
Pumping unit
Alfons Haar FPOG 100 Alfons Haar FPOG 150
A calculating and metering system
Alfons Haar MKA-2290 DKP Alfons Haar MKA-2290 DKP
Filter – water separator
Scientific Production Association “Agregat”, Velcon
Scientific Production Association “Agregat”, Velcon
Refueling hoses
Elaflex HD,  LT series
Elaflex HD,  LT series
The Inline valve 
Electromagnetic
Electromagnetic
A level gauge, a tank filling limiter system
Electronic
Electronic
An administration panel
Electronic Electronic
System of control for operator’s condition (“Dead man”)
Installed
Installed
System of blocking rooter’s movement (Interlock)
Installed
Installed
System of earthing
Two earthing reels with a 30 meters length cable
Two earthing reels with a 30 meters length cable
Painting
By client’s coloring map including a company logo
By client’s coloring map including a company logo
Configuration: Standard

Tank capacity:
20 000 liters

Tank material:
Aluminium alloy

Pump output flow at underwing refueling via one hose:
≥ 1 000 l/min

Recommended pump output flow at overwing refueling via refueling nozzle:
400 l/min

Dosing fuel system icing inhibitor agents:
0; 0,1% (as an option up to 0,3%)

Maximum allowable pressure in a dispensing hose before a bottom filling nozzle:
≤ 4,5 kg/sm2

Nominal filtration rating:
1–3 microns

Maximum allowable water content (by weight):
0,003%

Main consumption indicator error:
±0,25%

Dispensing hoses (number x length, m x diameter, mm):
1 x 25 x 63, 1 x 25 x 38

Bottom filling nozzle:
1 x Meggitt F145

Refueling nozzle:
1 x Elaflex ZVA-40

Pumping unit:
Alfons Haar FPOG 100

A calculating and metering system:
Alfons Haar MKA-2290 DKP

Filter – water separator:
Scientific Production Association “Agregat”, Velcon

Refueling hoses:
Elaflex HD, LT series

The Inline valve :
Electromagnetic

A level gauge, a tank filling limiter system:
Electronic

An administration panel:
Electronic

System of control for operator’s condition (“Dead man”):
Installed

System of blocking rooter’s movement (Interlock):
Installed

System of earthing:
Two earthing reels with a 30 meters length cable

Painting:
By client’s coloring map including a company logo

Configuration: Extended

Tank capacity:
20 000 liters

Tank material:
Aluminium alloy

Pump output flow at underwing refueling via one hose:
≥ 1 000 l/min

Pump output flow at underwing refueling via two hoses:
≥ 2 000 l/min

Recommended pump output flow at overwing refueling via refueling nozzle:
400 l/min

Dosing fuel system icing inhibitor agents:
0; 0,1% (as an option up to 0,3%)

Maximum allowable pressure in a dispensing hose before a bottom filling nozzle:
≤ 4,5 kg/sm2

Nominal filtration rating:
1–3 microns

Maximum allowable water content (by weight):
0,003%

Main consumption indicator error:
±0,25%

Dispensing hoses (number x length, m x diameter, mm):
2 x 25 x 50

Bottom filling nozzle:
1 x Meggitt F145

Refueling nozzle:
1 x Elaflex ZVA-40

Pumping unit:
Alfons Haar FPOG 150

A calculating and metering system:
Alfons Haar MKA-2290 DKP

Filter – water separator:
Scientific Production Association “Agregat”, Velcon

Refueling hoses:
Elaflex HD, LT series

The Inline valve:
Electromagnetic

A level gauge, a tank filling limiter system:
Electronic

An administration panel:
Electronic

System of control for operator’s condition (“Dead man”):
Installed

System of blocking rooter’s movement (Interlock):
Installed

System of earthing:
Two earthing reels with a 30 meters length cable

Painting:
By client’s coloring map including a company logo

Certificates
Aircraft Refueller 10 - Laureate of the contest "100 best goods of Russia"
Aircraft refueller 10 - Laureate of the regional contest "Best goods and services of the Penza region"
Aircraft Refueller 20 - Laureate of the contest "100 best goods of Russia"
Aircraft refueller 20 - Laureate of the regional contest "Best goods and services of the Penza region"
Aircraft Refueller 30 - Laureate of the contest "100 best goods of Russia"