30 m³
The aircraft refueller has been designed for airplanes refueling with filtered aviation fuel both pure and mixed with fuel system icing inhibitor agents. It is in full compliance with allowable loads on thoroughfare. It has a vehicle type approval and a certificate of conformity GOST 52 906-2008.
The aircraft refueller is used in airports of all the classes at air temperature from -400C to +400C and relative air humidity no more than 95%.
Configuration |
Standard |
Tank capacity |
30 000 liters |
Tank material |
High-strength aluminum alloy |
Pump output flow at underwing refueling via one hose via two hoses |
1 000 l/min 2 000 l/min |
Dosing fuel system icing inhibitor agents |
0.0%, 0.1+0,05% |
Maximum allowable pressure in a dispensing hose before a bottom filling nozzle |
4,5 kg/sm2 |
Nominal filtration rating |
3 microns |
Maximum allowable water content (by weight) |
0,003% |
Main consumption indicator error |
±0,25% |
Dispensing hoses (number x length, m x diameter, mm) |
2 x 30 x 50 |
Bottom filling nozzle |
2 x Meggitt F145 |
Pumping unit |
Alfons Haar SVP 150 |
A calculating and metering system |
Alfons Haar, МКА 2290 DKP |
Filter – water separator |
Faudi FW10-H-T-4-1093-10 |
Refueling hoses |
Elaflex, HD-50-C LT |
The Inline valve |
Maggitt |
A level gauge, a tank filling limiter system |
Electronic |
An administration panel |
Electronic/ Mechanical |
System of control for operator’s condition (“Dead man”) |
Installed |
System of blocking rooter’s movement (Interlock) |
Installed |
System of earthing |
Two earthing reels with a 30 meters length cable |
Painting |
By client’s coloring map including a company logo |
Tank capacity:
30 000 liters
Tank material:
High-strength aluminum alloy
Pump output flow at underwing refueling via one hose:
1 000 l/min
Pump output flow at underwing refueling via two hoses:
2 000 l/min
Dosing fuel system icing inhibitor agents:
0.0%, 0.1+0,05%
Maximum allowable pressure in a dispensing hose before a bottom filling nozzle:
4,5 kg/sm2
Nominal filtration rating:
3 microns
Maximum allowable water content (by weight):
0,003%
Main consumption indicator error:
±0,25%
Dispensing hoses (number x length, m x diameter, mm):
2 x 30 x 50
Bottom filling nozzle :
2 x Meggitt F145
Pumping unit:
Alfons Haar SVP 150
A calculating and metering system:
Alfons Haar, МКА 2290 DKP
Filter – water separator:
Faudi FW10-H-T-4-1093-10
Refueling hoses:
Elaflex, HD-50-C LT
The Inline valve :
Maggitt
A level gauge, a tank filling limiter system:
Electronic
An administration panel:
Electronic/ Mechanical
System of control for operator’s condition (“Dead man”):
Installed
System of blocking rooter’s movement (Interlock):
Installed
System of earthing:
Two earthing reels with a 30 meters length cable
Painting:
By client’s coloring map including a company logo